Temmuz-Ağustos-Eylül 2017 | Sayı: 2

KAYNAKLAR [1] Yokoi, S.: Study on the Prevention of Fire Spread Caused by Hot Upward Current, Report 34, Building Research Institute, Japan, 1960. [2] Yung D., Oleszkiewicz I., 1988. “Fire Spread via Exterior Walls of Buildings”, Proceedings of 4th Conference on Building Science and Technology, Toronto, Ontario, Canada, pp. 18-19. [3] Oleszkiewicz I., 1990. Fire Exposure to Exterior Walls and Flame Spread on Combustible Cladding, Fire Technology 26(4), p. 357. [4] Klopovic S., Turan ÖF., 1998. Flames Venting Externally During Full-scale Flashover Fires: Two Sample Ventilation Cases, Fire Safety Journal 31(2), p. 117. [5] China Daily, 2009. CCTV Hotel Fire Caused by Fireworks: official, http://www.chinadaily.com.cn/china/2009-02/10/ content_7461514.htm. [6] Xinhua Net, 2009. CCTV Official Detained over Massive Fire, http:// news.xinhuanet.com/english/2009-02/12/content_10805915. htm. [7] Xinhua Net, 2010. Death Toll of Shanghai Fire Climbs to 53, http://news.xinhuanet.com/english2010/china/2010- 11/16/c_13608737.htm. [8] Xinhua Net, 2010. Shanghai High-rise Fire Death Toll Rises to 58, http://news.xinhuanet.com/english2010/china/2010- 11/19/c_13613065.htm. [9] Xinhua Net, 2011. Five-star Hotel on Fire in Northeast China City, http://news.xinhuanet.com/english2010/china/2011- 02/03/c_13717480.htm. [10] Ministry of Public Security of People’s Republic of China: GB 8624- 1997: Classification on Burning Behavior for BuildingMaterials, 1997. (in Chinese) [11] DIN 4102-1: Brandverhalten von Baustoffen und Bauteilen; Baustoffe; Begriffe, Anforderungen und Prüfungen, 1981. (in German) [12] Ministry of Public Security of People’s Republic of China GB 8624- 2006: Classification for Burning Behavior of Building Materials and Products, 2006. (in Chinese) [13] EN13501-1: Fire Classification of Construction Products and Building Elements –Part 1: Classification Using Date Form Reaction to Fire tests, 2002. [14] Ministry of Public Security of People’s Republic of China: GB 50016-2006: Code of Design on Building Fire Protection and Prevention, China Planning Press, Beijing, 2006. (in Chinese) [15] Ministry of Public Security of People’s Republic of China GB 50045- 2005: Code for Fire Protection Design of Tall Buildings, China Planning Press, Beijing, 2006. (in Chinese) [16] BS 8414-1: Fire Performance of External Cladding Systems - Part 1: Test Method for Non-loadbearing External Cladding Systems Applied to the Face of the Building, 2002. Dış duvar tipi Kullanım şekli Yükseklik sınırları (H, metre) İzolasyon malzemelerinin yanıcılığı Açıklamalar Perde duvarı olmayan dış duvar Konut binası H≥ 100 m A 54 m <H≤ 100m A1, veya B1* * Eğer B1 kullanılıyorsa yüzey koruması (1) sağlanmalıdır. 27m<H≤54 m A1, B1* veya B2* * Eğer B1 kullanılıyorsa yüzey koruması (2) sağlanmalıdır. Eğer B2 kullanılıyorsa yüzey koruması (2) sağlanmalı ve yatay yangın bariyeri her kata koyulmalıdır. H≤ 27m A1, B1* veya B2* * Eğer B1 kullanılıyorsa yüzey koruması (3) sağlanmalıdır. Eğer B2 kullanılıyorsa yüzey koruması (3) sağlanmalı ve yatay yangın bariyeri her kata koyulmalıdır Konut dışı binalar H >50 m A 24 m<H≤50 m A veya B1 *Eğer B1 kullanılıyorsa yüzey koruması (2) sağlanmalıdır. H≤24m A1, B1* veya B2* * Eğer B1 veya B2 kullanılıyorsa yüzey koruması (2) sağlanmalıdır. Perde duvarlı dış duvar tipi Tüm binalar H>24m A H ≤24m A veya B1* * Eğer B1 kullanılıyorsa yüzey koruması (2) sağlanmalı ve içi boş oyuk kısımlar için yangın stopları her kata koyulmalıdır Tablo 4. Yönetmelik taslağında önerilen şartlar 42 TÜYAK YANGIN MÜHENDİSLİĞİ SAYI 2 TÜYAK Yangın Mühendisliği Dergisi, Sayı 2, s 36-42, 2017

RkJQdWJsaXNoZXIy OTEzMQ==